Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
400W
16.67A
90-264Vac
140.0 x 88.9 x 44.4 mm
5.51” x 3.50” x 1.75”
0.605 kg (1.33 lb)
Model | Description |
---|---|
MDS-400ADB24 AB | Without Remote On/Off |
24V
400W
16.67A
90-264Vac
140.0 x 88.9 x 44.4 mm
5.51” x 3.50” x 1.75”
0.605 kg (1.33 lb)
Model | Description |
---|---|
MDS-400ADB24 AB | Without Remote On/Off |
Output Current
16.67A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
400W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
±0.5%
|
Load Regulation
±1%
|
PARD
-
|
Start-up Time
2000ms @ 115Vac
|
Hold-up Time
10ms@115Vac, with 400W load
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 50-100% load
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
100ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
5.5A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
92% @ 115Vac/60Hz
93% @ 230Vac/50Hz, Reference |
Inrush Current
40A@230Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.95 @ 115V/50Hz, 230V/50Hz, full load
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Enclosed cover(SPCC)
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.605 kg (1.33 lb)
|
Dimensions
140.0 x 88.9 x
44.4 mm
5.51” x 3.50” x 1.75” |
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
|
Shock Test (Operating)
-
|
Operating Temperature
Absolute Maximum/Minimum Rating.
-10°C to +70°C. Linearly derate from 100% load at 50°C, to 50% load at 70°C (2.5%/ degree centigrade) for forced air. Note: see power de-rating curves below |
Storage Temperature
-40°C to +85°C
|
Power De-rating
Linearly derate from 100% load at 50°C, to 50% load at 70°C (2.5%/ degree centigrade)
|
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
5,000 meters (16402 feet)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
135% of rated voltage, Latch Mode
|
Overload / Overcurrent
Main output 160% of rated current
Standby 3A max Hiccup Mode(Non-Latching, Auto-Recovery) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
500 kHrs based on Telecordia SR-332
|
Expected Cap Life Time
16CFM Air Flow 500 kHrs based on Telecordia SR-332 Operating life at 115Vac, 400W, ambient 25 °C, 16CFM Air Flow: 26,280Hrs
|
Safety Certificate
-
|
Electrical Safety
IEC60950-1, IEC62368-1 CB report
TUV60950-1 UL60950-1+CAN/CSA60950-1 |
CE
MDD Directive 93/42/EEC
|
Medical Safety
IEC 60601-1 CB report
TUV EN 60601-1 UL 60601-1+CAN/CSA 60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500Vac(PSU can support PoE applications with Primary to FG 2500Vac test.) Output to/Ground(1XMOPP): 1500Vac ( Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
EN55011 & compliant with EN55032, FCC Title 47:Class B
|
Immunity
-
|
Harmonic Current Emissions
IEC61000-3-2 Meet Class D limit
|
Voltage Fluctuation and Flicker
IEC61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
2500W
52.1A
85-264 Vac
24V
2500W
104.2A
85-264 Vac
24V
2000W
83.3A
80 - 275 Vac
48V
200W
-
90-264 Vac